Global Distributor Network
Pyroplex Golbal Distributers
  Join Newsletter





 Glazing Systems - 30 MinutesDownload PdfDownload Pdf


Pyroplex fire-resisting glazing systems offer a range of solutions for glazing vision panels in fire doors. Pyroplex fire-resisting glazing systems are available for 30 minute applications.

Pyroplex 30 minute glazing systems are fully flexible and supplied in slimline reels for easy storage and to minimise wastage. They are also approved for use on slimline economical beads.

Pyroplex fire-resisting 30 minute glazing systems are tested to BS476: Part 22: Clauses 7 & 8 and other international standards. They are compliant with the requirements of CERTIFIRE TS25.

CERTIFIRE CertificateNo. CF346 & CF348.

Fire Resisting glazing system
Product Profiles
Fire Resisting glazing system
Field of Application
Pyroplex 30 minute glazing systems have been specifically designed for use in glazed apertures in fire doors in the following applications:
• Glazed apertures in fire resisting timber doors and steel doors.

Product Features
• Supplied on continuous reels for dispensing applications, ease of storage and to reduce wastage in cut-offs. Supplied with a high performance self-adhesive backing for ease of application and installation.
• Pyroplex intumescent material is totally unaffected by water, robust,‘non-flaking’ and difficult to tear.

Product Data
Part
Number
For Use With
Insulating Glass
For Use With
Non-Insulating Glass
30049 Yes Yes
30054 Yes No
8193 Yes Yes

Product Testing;
Pyroplex 30 minute glazing systems have been tested to the requirements of CERTIFIRE TS25 and other international standards, including British Standards BS476: Part 22:1987, clause 7 & 8.

Test Reports & International Standards
CERTIFIRE CF346 & CF348
Mid-East Listing Scheme ME0042 & ME0043
Bodycote Warringtonfire 136934, 136935, 137714, 139878, 165278
  Installation Instructions
All doors must be lined with a 6mm hardwood liner around the perimeter of the aperture. Failure to line the aperture will invalidate the CERTIFIRE Approval.
1. Unwind the glazing system from the coil. Remove the release liner from the product. Fit the product to the bead.
2. Mitre cut the bead (with glazing system installed) to fit the aperture. Install one complete side of the beading system using M5 x 50 stainless steel screws at 150mm centres.
3. Cut glass to fit aperture with a tolerance of +/-2mm and install. Repeat steps for opposite side of the door.


Copyright Pyroplex 2008

Email:info@pyroplex.com